Recording characteristics of electrical impedance-electromyography needle electrodes.


ABSTRACT: OBJECTIVE:Needle EMG remains the standard clinical test for neuromuscular disease (NMD) assessment, but it only characterizes myofiber membrane depolarization. On the other hand, electrical impedance provides non-electrically active structural and compositional data of tissues. Here, we designed a prototype of needle electrode integrating electrical impedance and EMG measurement capabilities, the so-called I-EMG needle electrode. APPROACH:We use finite element method models to study the impedance recording characteristics of I-EMG needle electrodes. The simulated electrical and mechanical design specifications are then manufactured to create a prototype of an I-EMG needle electrode. We pilot these new needle electrodes by conducting in vivo impedance measurements with muscle at rest on healthy wild-type (wt, n  =  5) and muscular dystrophy (mdx, n  =  5) mice. Comparisons between wt and mdx mice are performed using Mann-Whitney test, two-tailed, p  <  0.05. The electrical characterization of the EMG electrode in the developed I-EMG needles was performed in vitro on saline solution and through EMG detection in wt animal at rest and during voluntary contractions. RESULTS:Muscle impedance demonstrate good repeatability (p  <  0.05 and p  <  0.005 for resistance and reactance at 50 kHz, respectively) and agreement between different I-EMG needles. Impedance data allows us to discriminate between mdx and wt muscle (p  <  0.05 and p  <  0.005 for resistance and reactance at 10 kHz, respectively). EMG broadband noise power and peak amplitude using the I-EMG needle were similar to that of a commercial monopolar EMG needle. EMG recordings using the I-EMG needle measured electrical activity similar to a standard monopolar needle with muscle at rest and during voluntary contraction. SIGNIFICANCE:Needle I-EMG technology may offer the opportunity to enhance the diagnostic capability and quantification of NMD beyond that possible with either impedance or EMG techniques separately. Ultimately, needle I-EMG could serve as a new bedside tool to assess NMD without increasing the complexity or duration of the EMG test.

SUBMITTER: Kwon H 

PROVIDER: S-EPMC5997185 | biostudies-literature | 2018 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Recording characteristics of electrical impedance-electromyography needle electrodes.

Kwon H H   Di Cristina J F JF   Rutkove S B SB   Sanchez B B  

Physiological measurement 20180522 5


<h4>Objective</h4>Needle EMG remains the standard clinical test for neuromuscular disease (NMD) assessment, but it only characterizes myofiber membrane depolarization. On the other hand, electrical impedance provides non-electrically active structural and compositional data of tissues. Here, we designed a prototype of needle electrode integrating electrical impedance and EMG measurement capabilities, the so-called I-EMG needle electrode.<h4>Approach</h4>We use finite element method models to stu  ...[more]

Similar Datasets

| S-EPMC10698741 | biostudies-literature
| S-EPMC6646361 | biostudies-literature
| S-EPMC5762724 | biostudies-literature
| S-EPMC9012450 | biostudies-literature
| S-EPMC9608147 | biostudies-literature
| S-EPMC6603149 | biostudies-literature
| S-EPMC7534001 | biostudies-literature
| S-EPMC8714743 | biostudies-literature
| S-EPMC6188074 | biostudies-literature
| S-EPMC10922034 | biostudies-literature