The reliability of carotid ultrasound in determining the return of pulsatile flow: A pilot study.


ABSTRACT: Manual palpation of pulses is unreliable in detecting pulsatile flow in human participants, complicating the assessment of return of spontaneous circulation after cardiac arrest. Ultrasound may offer an alternative. This study's objective was to investigate whether return of pulsatile flow in humans can be reliably assessed by common carotid artery ultrasound. We conducted a single-blinded randomised study of common carotid artery ultrasound using 20 cardiopulmonary bypass patients to model the return of pulsatile flow. Synchronised time-stamped videos of radial artery invasive blood pressure and 10 two-dimensional or 10 colour Doppler ultrasounds were recorded. Three independent reviewers recorded the timestamp where they considered pulsatile flow was first visible on ultrasound. Ultrasou

SUBMITTER: Germanoska B 

PROVIDER: S-EPMC6042301 | biostudies-literature | 2018 May