Component design is one of the contributory factors affecting the postoperative flexion angle. The purpose of this study was to compare short-term outcomes of flat surface and medial pivot designs in posterior cruciate-retaining (CR) total knee arthroplasty (TKA).Methods
A retrospective, case-control, and observational cohort study consisted of matched-pairs of the flat surface design (Hi-Tech Knee II) and the medial pivot design (FINE Knee) in CR-TKA with a two-year follow-up period.Results
Hi-Tech Knee II and FINE knee groups each included 7 males and 38 females. Surgical time was significantly shorter in the FINE Knee group than in the Hi-Tech Knee II group (104.8 min versus 154.9 min, p = 0.001). Estimated total blood loss was significantly lower in t
SUBMITTER: Nakamura J