Ontology highlight
ABSTRACT: Background
Idiopathic intracranial hypertension (IIH) is a condition of abnormally high intracranial pressure with an unknown etiology. The objective of this study is to characterize craniospinal compliance and measure the cerebrospinal fluid (CSF) pressure waveform as CSF is passively drained during a diagnostic and therapeutic lumbar puncture (LP) in IIH.Methods
Eighteen subjects who met the Modified Dandy Criteria, including papilledema and visual field loss, received an ultrasound guided LP where CSF pressure (CSFP) was recorded at each increment of CSF removal. Joinpoint regression models were used to calculate compliance from CSF pressure and the corresponding volume removed at each increment for each subject. Twelve subjects had their CSFP waveform recorded with an e
SUBMITTER: Okon MD
PROVIDER: S-EPMC6069551 | biostudies-literature | 2018 Aug
REPOSITORIES: biostudies-literature