Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation.
Ontology highlight
ABSTRACT: The fusion of 3D anatomical models derived from high-fidelity pre-interventional computed tomography angiography (CTA), and x-ray (XR) fluoroscopy to facilitate anatomical guidance is of huge interest for complex cardiac interventions like TAVI procedures with cerebral protection. Co-registration of CTA and XR has been introduced either based on additional intraoperative non-/contrast-enhanced cone-beam computed tomography (CBCT) or two separate aortograms. With the related increase of radiation exposure and/or contrast agent (CA) dose, a potential additional risk for the patient is introduced. Here, we propose a modified co-registration approach making use of arteriograms of the iliofemoral arteries, routinely performed during the femoral puncture and sheath introduction. On-the-fly refin
SUBMITTER: Vernikouskaya I
PROVIDER: S-EPMC6101552 | biostudies-literature | 2018 Jun
REPOSITORIES: biostudies-literature
ACCESS DATA