Diagnostic value of PD-1 mRNA expression combined with breast ultrasound in breast cancer patients.


ABSTRACT:

Introduction

This study explored the value of measuring programmed death 1 (PD-1) in peripheral blood, combined with breast ultrasound using the Breast Imaging Reporting and Data System (BI-RADS) classification, for differentiation between benign and malignant breast tumors.

Materials and methods

We enrolled 113 patients with breast cancer and 66 patients with benign breast tumors who were admitted to Hangzhou First People's Hospital from September 2014 to August 2017. The mRNA level of PD-1 was detected by quantitative real-time polymerase chain reaction.

Results

The mRNA levels of PD-1 were significantly higher in the peripheral blood of patients with breast cancer than those in patients with benign breast tumors. The diagnostic sensitivity of PD-1 mRNA expression was 0.805, the specificity was 0.788, and the area under the curve (AUC) was 0.848 (P < 0.001); the sensitivity of breast ultrasound-based BI-RADS classification was 0.752, the specificity was 0.909, and the AUC was 0.906 (P < 0.001); and the combined sensitivity, specificity, and AUC of the two assays were 0.920, 0.879, and 0.938, respectively (P < 0.001). Progesterone receptor-positive breast cancer patients exhibited high levels of PD-1 expression (P < 0.001).

Conclusion

This study suggests that the measurement of PD-1 combined with breast ultrasound-based BI-RADS classification represents a significant improvement for breast cancer diagnosis compared with diagnoses based on either method alone.

SUBMITTER: Fang J 

PROVIDER: S-EPMC6118870 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

Diagnostic value of PD-1 mRNA expression combined with breast ultrasound in breast cancer patients.

Fang Jianhua J   Shao Yi Y   Su Jiezhi J   Wan Ying Y   Bao Lingyun L   Wang Wei W   Kong Fanlei F  

Therapeutics and clinical risk management 20180828


<h4>Introduction</h4>This study explored the value of measuring programmed death 1 (PD-1) in peripheral blood, combined with breast ultrasound using the Breast Imaging Reporting and Data System (BI-RADS) classification, for differentiation between benign and malignant breast tumors.<h4>Materials and methods</h4>We enrolled 113 patients with breast cancer and 66 patients with benign breast tumors who were admitted to Hangzhou First People's Hospital from September 2014 to August 2017. The mRNA le  ...[more]

Similar Datasets

| S-EPMC11625769 | biostudies-literature
| S-EPMC11411459 | biostudies-literature
| S-EPMC7607072 | biostudies-literature
| S-EPMC7285818 | biostudies-literature
| S-EPMC10005981 | biostudies-literature
| S-EPMC8690901 | biostudies-literature
| S-EPMC6607404 | biostudies-literature
| S-EPMC4314004 | biostudies-literature
| S-EPMC2831058 | biostudies-literature