ABSTRACT: Purpose
Evaluation of postoperative artificial iris prosthesis-related complications.Design
Retrospective cohort study.Methods
Fifty-one consecutive patients underwent pupillary reconstruction using an artificial iris implant made from silicone between 2011 and 2015. Quantity and quality of complications were subclassified into three groups including mild, moderate, and severe complications. Their management and the learning curve were evaluated.Results
In total, 13 (25.5%) of 51 included artificial iris implantations showed unexpected events in various degrees: mild complications: recurrent bleeding (n=1, 2.0%), slight but stable iris deviation (n=1, 2.0%), capsular fibrosis (n=2, 3.9%); moderate complications: suture cutting through th