Unknown

Dataset Information

0

Test-retest reliability and convergent validity of (R)-[11C]PK11195 outcome measures without arterial input function.


ABSTRACT:

Purpose

The PET radioligand (R)-[11C]PK11195 is used to quantify the 18-kDa translocator protein (TSPO), a marker for glial activation. Since there is no brain region devoid of TSPO, an arterial input function (AIF) is ideally required for quantification of binding. However, obtaining an AIF is experimentally demanding, is sometimes uncomfortable for participants, and can introduce additional measurement error during quantification. The objective of this study was to perform an evaluation of the test-retest reliability and convergent validity of techniques used for quantifying (R)-[11C]PK11195 binding without an AIF in clinical studies.

Methods

Data from six healthy individuals who participated in two PET examinations, 6 weeks apart, were analyzed. Regional non-displaceable binding potential (BPND) values were calculated using the simplified reference tissue model, with either cerebellum as reference region or a reference input derived using supervised cluster analysis (SVCA). Standardized uptake values (SUVs) were estimated for the time interval of 40-60 min.

Results

Test-retest reliability for BPND estimates were poor (80% of ICCs ND estimates derived without an AIF were not correlated with BPND, total or specific distribution volume from the 2TCM using an AIF (all R2?ConclusionsCaution is warranted when interpreting patient-control comparisons employing (R)-[11C]PK11195 outcome measures obtained without an AIF.

SUBMITTER: Plaven-Sigray P 

PROVIDER: S-EPMC6265355 | biostudies-literature | 2018 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Test-retest reliability and convergent validity of (R)-[<sup>11</sup>C]PK11195 outcome measures without arterial input function.

Plavén-Sigray Pontus P   Matheson Granville James GJ   Cselényi Zsolt Z   Jucaite Aurelija A   Farde Lars L   Cervenka Simon S  

EJNMMI research 20181129 1


<h4>Purpose</h4>The PET radioligand (R)-[<sup>11</sup>C]PK11195 is used to quantify the 18-kDa translocator protein (TSPO), a marker for glial activation. Since there is no brain region devoid of TSPO, an arterial input function (AIF) is ideally required for quantification of binding. However, obtaining an AIF is experimentally demanding, is sometimes uncomfortable for participants, and can introduce additional measurement error during quantification. The objective of this study was to perform a  ...[more]

Similar Datasets

| S-EPMC7868437 | biostudies-literature
| S-EPMC4582746 | biostudies-literature
| S-EPMC6694546 | biostudies-literature
| S-EPMC8147413 | biostudies-literature
| S-EPMC3105910 | biostudies-literature