Predicting Patient-ventilator Asynchronies with Hidden Markov Models.
Ontology highlight
ABSTRACT: In mechanical ventilation, it is paramount to ensure the patient's ventilatory demand is met while minimizing asynchronies. We aimed to develop a model to predict the likelihood of asynchronies occurring. We analyzed 10,409,357 breaths from 51 critically ill patients who underwent mechanical ventilation >24 h. Patients were continuously monitored and common asynchronies were identified and regularly indexed. Based on discrete time-series data representing the total count of asynchronies, we defined four states or levels of risk of asynchronies, z1 (very-low-risk) - z4 (very-high-risk). A Poisson hidden Markov model was used to predict the probability of each level of risk occurring in the next period. Long periods with very few asynchronous events, and consequently very-low-risk, were more
SUBMITTER: Marchuk Y
PROVIDER: S-EPMC6279839 | biostudies-literature | 2018 Dec
REPOSITORIES: biostudies-literature
ACCESS DATA