ABSTRACT: Objectives
To determine whether a dual-camera markerless motion capture system can be used for lower limb kinematic evaluation in athletes in a preseason screening setting.Design
Descriptive laboratory study.Setting
Laboratory setting.Participants
Thirty-four (n=34) healthy athletes.Main outcome measures
Three dimensional lower limb kinematics during three functional tests: Single Leg Squat (SLS), Single Leg Jump, Modified Counter-movement Jump. The tests were simultaneously recorded using both a marker-based motion capture system and two Kinect v2 cameras using iPi Mocap Studio software.Results
Excellent agreement between systems for the flexion/extension range of motion of the shin during all tests and for the thigh abduction/adduction duri
SUBMITTER: Kotsifaki A
PROVIDER: S-EPMC6307561 | biostudies-literature | 2018