Introduction

New treatments to inhibit neointimal formation after percutaneous transluminal angioplasty (PTA) are needed for patients undergoing chronic hemodialysis (HD). We compared the efficacy and safety of AMG0102, a balloon catheter containing nuclear factor κB (NF-κB) decoy oligodeoxynucleotide (ODN) with the PTA balloon catheter (control group) for arteriovenous fistula (AVF) stenosis.

Methods

In total, 175 patients (age ≥20 years, undergoing HD, with venous stenosis at the anastomotic region) were registered in this prospective open-label, randomized study. Patients were followed postoperatively for 36 weeks. The duration of primary patency on the targeted venous stenosis site (primary endpoint) was estimated by the Kaplan-Meier method.

Results

A lower resten