Unknown

Dataset Information

Assessing the Feasibility of Providing a Real-Time Response to Seizures Detected With Continuous Long-Term Neonatal Electroencephalography Monitoring.


ABSTRACT:

Purpose

Continuous video electroencephalography (cEEG) monitoring is the recommended gold standard of care for at-risk neonates but is not available in many Neonatal Intensive Care Units (NICUs). To conduct a randomized treatment trial of levetiracetam for the first-line treatment of neonatal seizures (the NEOLEV2 trial), we developed a monitoring infrastructure at five NICUs, implementing recent technological advancements to provide continuous video EEG monitoring and real-time response to seizure detection. Here, we report on the feasibility of providing this level of care.

Methods

Twenty-five key informant interviews were conducted with study neurologists, neonatologists, coordinators, and EEG technicians from the commercial EEG monitoring company Corticare. A general ind

SUBMITTER: Sharpe C 

PROVIDER: S-EPMC6320287 | biostudies-literature | 2019 Jan

REPOSITORIES: biostudies-literature