Intensive Blood Pressure Treatment for Resistant Hypertension.
Ontology highlight
ABSTRACT: Evidence about the target blood pressure (BP) in patients with resistant hypertension is limited. The present study aimed to assess the efficacy of intensive BP treatment (systolic BP target, <120 mm Hg) versus standard BP treatment (systolic BP target, <140 mm Hg) in patients with resistant hypertension. This is a secondary analysis using data from SPRINT (Systolic Blood Pressure Intervention Trial). This study included 1397 patients with resistant hypertension and 7698 without resistant hypertension. Using the Cox proportional hazards model, we compared time to first occurrence of a major adverse cardiovascular event (cardiovascular death, myocardial infarction, and stroke) between the intensive and standard BP treatment groups. Mean follow-up was 3.1 years; major adverse cardiovascular
SUBMITTER: Tsujimoto T
PROVIDER: S-EPMC6343947 | biostudies-literature | 2019 Feb
REPOSITORIES: biostudies-literature
ACCESS DATA