Accuracy and Operational Characteristics of Xpert Human Immunodeficiency Virus Point-of-Care Testing at Birth and Until Week 6 in Human Immunodeficiency Virus-exposed Neonates in Tanzania.


ABSTRACT:

Background

Point-of-care (PoC) systems for early infant diagnosis (EID) may improve timely infant human immunodeficiency virus (HIV) management. Experiences within African public health settings are limited.

Methods

We evaluated the accuracy and operational feasibility of the Xpert HIV-1 Qual for PoC-EID testing, using fresh blood and dried blood spots (DBS) samples at obstetric health facilities in Tanzania at birth and at postpartum weeks 1, 2, 3, and 6 in HIV-exposed infants. Test results were confirmed using TaqMan DBS HIV-deoxyribonucleic acid and/or plasma HIV-ribonucleic acid (RNA) testing.

Results

At week 6, 15 (2.5%) out of 614 infants were diagnosed with HIV; 10 (66.7%) of them at birth (median HIV-RNA 4570 copies/mL). At birth, the Xpert-PoC and Xpert-DBS w