Unknown

Dataset Information

Particle size and gastrointestinal absorption influence tiotropium pharmacokinetics: a pilot bioequivalence study of PUR0200 and Spiriva HandiHaler.


ABSTRACT:

Aims

Plasma pharmacokinetics permit the assessment of efficacy and safety of inhaled drugs, and possibly their bioequivalence to other inhaled products. Correlating drug product attributes to lung deposited dose is important to achieving equivalence. PUR0200 is a spray-dried formulation of tiotropium that enables more efficient lung delivery than Spiriva® HandiHaler® (HH). The ratio of tiotropium lung-to-oral deposition in PUR0200 was varied to investigate the impact of particle size on tiotropium pharmacokinetics, and the contribution of oral absorption to tiotropium exposure was assessed using charcoal block.

Methods

A seven-period, single-dose, crossover study was performed in healthy subjects. PUR0200 formulations differing in dose and aerodynamic p

SUBMITTER: Perry J 

PROVIDER: S-EPMC6379222 | biostudies-literature | 2019 Mar

REPOSITORIES: biostudies-literature