Unknown

Dataset Information

Comparative study of stress characteristics in surrounding bone during insertion of dental implants of three different thread designs: A three-dimensional dynamic finite element study.


ABSTRACT: The objective of this study is to evaluate the stress distribution characteristics around three different dental implant designs during insertion into bone, using dynamic finite element stress analysis. Dental implant placement was simulated using finite element models. Three implants with different thread and body designs (Model 1: root form implant with three different thread shapes; Model 2: tapered implant with a double-lead thread; and Model 3: conical tapered implant with a constant buttress thread) were assigned to insert into prepared bone cavity models until completely placed. Stress and strain distributions were descriptively analyzed. The von Mises stresses within the surrounding bone were measured. At the first 4-mm depth of implant insertion, maximum stress within cortical bon

SUBMITTER: Udomsawat C 

PROVIDER: S-EPMC6392841 | biostudies-literature | 2019 Feb

REPOSITORIES: biostudies-literature