Physical and Mechanical Evaluation of Five Suture Materials on Three Knot Configurations: An in Vitro Study.
Ontology highlight
ABSTRACT: The aim of this study was to evaluate and compare the mechanical properties of five suture materials on three knot configurations when subjected to different physical conditions. Five 5-0 (silk, polyamide 6/66, polyglycolic acid, glycolide-e-caprolactone copolymer, polytetrafluoroethylene) suture materials were used. Ten samples per group of each material were used. Three knot configurations were compared A.2=1=1 (forward⁻forward⁻reverse), B.2=1=1 (forward⁻reverse⁻forward), C.1=2=1 (forward⁻forward⁻reverse). Mechanical properties (failure load, elongation, knot slippage/breakage) were measured using a universal testing machine. Samples were immersed in three different pH concentrations (4,7,9) at room temperature for 7 and 14 days. For the thermal cycle process, sutures were immersed in tw
SUBMITTER: Abellan D
PROVIDER: S-EPMC6432448 | biostudies-literature | 2016 Apr
REPOSITORIES: biostudies-literature
ACCESS DATA