Estimating three-dimensional outflow and pressure gradients within the human eye.
Ontology highlight
ABSTRACT: In this paper we set the previously reported pressure-dependent, ordinary differential equation outflow model by Smith and Gardiner for the human eye, into a new three-dimensional (3D) porous media outflow model of the eye, and calibrate model parameters using data reported in the literature. Assuming normal outflow through anterior pathways, we test the ability of 3D flow model to predict the pressure elevation with a silicone oil tamponade. Then assuming outflow across the retinal pigment epithelium is normal, we test the ability of the 3D model to predict the pressure elevation in Schwartz-Matsuo syndrome. For the first time we find the flow model can successfully model both conditions, which helps to build confidence in the validity and accuracy of the 3D pressure-dependent outflow mod
SUBMITTER: Smith DW
PROVIDER: S-EPMC6456205 | biostudies-literature | 2019
REPOSITORIES: biostudies-literature
ACCESS DATA