Actual condition survey regarding mismatch of measurements between radioimmunoassay and enzyme-linked immunosorbent assay tests for anti-glutamic acid decarboxylase antibody in real-world clinical practice.
Ontology highlight
ABSTRACT: Anti-glutamic acid decarboxylase antibody (GADA) is an important islet cell-associated autoantibody for the diagnosis of autoimmune type 1 diabetes mellitus. In Japan, the GADA assay kit was recently changed from radioimmunoassay (RIA) to enzyme-linked immunosorbent assay (ELISA). Thereafter, a mismatched measurement between the two tests became apparent in clinical situations. The present study aimed to clarify the actual extent of mismatch between the two measurements on a larger-scale real-world clinical practice. In this cross-sectional non-local/non-hospital-based study, we collected anonymized data on GADA levels of 598 participants, who were simultaneously measured with GADA-RIA and GADA enzyme-linked immunosorbent assay tests. We found that 34% of the GADA-RIA-positive participants
SUBMITTER: Oikawa Y
PROVIDER: S-EPMC6497777 | biostudies-literature | 2019 May