Semi-automated analysis of 4D flow MRI to assess the hemodynamic impact of intracranial atherosclerotic disease.


ABSTRACT:

Purpose

This study evaluated the feasibility of using 4D flow MRI and a semi-automated analysis tool to assess the hemodynamic impact of intracranial atherosclerotic disease (ICAD). The ICAD impact was investigated by evaluating pressure drop (PD) at the atherosclerotic stenosis and changes in cerebral blood flow distribution in patients compared to healthy controls.

Methods

Dual-venc 4D flow MRI was acquired in 25 healthy volunteers and 16 ICAD patients (ICA, N = 3; MCA, N = 13) with mild (<50%), moderate (50-69%), or severe (>70%) intracranial stenosis. A semi-automated analysis tool was developed to quantify velocity and flow from 4D flow MRI and to evaluate cerebral blood flow redistribution. PD at stenosis was estimated using the Bernoulli equation. The PD calculation w

SUBMITTER: Vali A 

PROVIDER: S-EPMC6510639 | biostudies-literature | 2019 Aug

REPOSITORIES: biostudies-literature