A microfluidic based biosensor for rapid detection of Salmonella in food products.
Ontology highlight
ABSTRACT: An impedance based microfluidic biosensor for simultaneous and rapid detection of Salmonella serotypes B and D in ready-to-eat (RTE) Turkey matrix has been presented. Detection of Salmonella at a concentration as low as 300 cells/ml with a total detection time of 1 hour has been achieved. The sensor has two sensing regions, with each formed from one interdigitated electrode array (IDE array) consisting of 50 finger pairs. First, Salmonella antibody type B and D were prepared and delivered to the sensor to functionalize each sensing region without causing any cross contamination. Then the RTE Turkey samples spiked with Salmonella types B and D were introduced into the biosensor via the antigen inlet. The response signal resulted from the binding between Salmonella and its specific antibody
SUBMITTER: Liu J
PROVIDER: S-EPMC6516674 | biostudies-literature | 2019
REPOSITORIES: biostudies-literature
ACCESS DATA