Compromised Air Quality and Healthcare Safety from Smoking inside Hospitals in Shantou, China.


ABSTRACT: Achieving smoke-free healthcare facilities remains a great challenge in countries with a high smoking prevalence and weak regulation. Assessment of the impact of environmental tobacco smoke (ETS) and its constituent PM2.5 on the air quality in Chinese hospitals has not been reported. In this study, we conducted air quality surveys by measuring real-time PM2.5 concentrations with Dylos Air Quality Monitors in five tertiary hospitals in Shantou, China during summer (July-August 2016) and winter (November-February 2017). Twenty-eight-day surveys inside the hospitals showed median PM2.5 concentrations above the China Air Quality Standard in elevator lobbies (51.0 μg/m3, IQR 34.5-91.7), restrooms (40.2, 27.1-70.3), and corridors (36.5, 23.0-77.4). Evi