Ontology highlight
ABSTRACT: Background
In recent years, criticism of the percentage range approach for individualised exercise prescription has intensified and we were concerned that sub-optimal exercise dose (especially intensity) may be in part responsible for the variability in the effectiveness of cardiac rehabilitation (CR) programmes in the United Kingdom (UK). The aim was to investigate the fidelity of a structured Phase III CR programme, by monitoring and quantifying exercise training intensity.Design
Observational study.Methods
The programme comprised 16 sessions over 8 weeks, where patients undertook an interval, circuit training approach within national guidelines for exercise prescription (40-70% heart rate reserve [HRR]). All patients wore an Apple Watch (Series 0 or 2, Watch OS2.
SUBMITTER: Khushhal A
PROVIDER: S-EPMC6563987 | biostudies-literature | 2019