Characterizing the impact of pressure on virus filtration processes and establishing design spaces to ensure effective parvovirus removal.
Ontology highlight
ABSTRACT: Virus filtration provides robust removal of potential viral contaminants and is a critical step during the manufacture of biotherapeutic products. However, recent studies have shown that small virus removal can be impacted by low operating pressure and depressurization. To better understand the impact of these conditions and to define robust virus filtration design spaces, we conducted multivariate analyses to evaluate parvovirus removal over wide ranges of operating pressure, solution pH, and conductivity for three mAb products on Planova™ BioEX and 20N filters. Pressure ranges from 0.69 to 3.43 bar (10.0-49.7 psi) for Planova BioEX filters and from 0.50 to 1.10 bar (7.3 to 16.0 psi) for Planova 20N filters were identified as ranges over which effective removal of parvovirus is achieved f
SUBMITTER: Strauss D
PROVIDER: S-EPMC6585929 | biostudies-literature | 2017 Sep
REPOSITORIES: biostudies-literature