ABSTRACT: Purpose
To obtain a fast and robust fat-water separation with simultaneous estimation of water T1 , fat T1 , and fat fraction maps.Methods
We modified an MR fingerprinting (MRF) framework to use a single dictionary combination of a water and fat dictionary. A variable TE acquisition pattern with maximum TE = 4.8 ms was used to increase the fat-water separability. Radiofrequency (RF) spoiling was used to reduce the size of the dictionary by reducing T2 sensitivity. The technique was compared both in vitro and in vivo to an MRF method that incorporated 3-point Dixon (DIXON MRF), as well as Cartesian IDEAL with different acquisition parameters.Results
The proposed dictionary-based fat-water separation technique (DBFW MRF) successfully p