Soil Water Sensor Performance and Corrections with Multiple Installation Orientations and Depths under Three Agricultural Irrigation Treatments.


ABSTRACT: Performance evaluations and corrections of soil water sensors have not been studied using different installation orientations under various irrigation treatments in the Texas High Plains. This study evaluated the performance of four sensors using factory calibration and derived field corrections as compared to calibrated neutron moisture meters (NMMs). Sensor performance was assessed using horizontal insertion, laid horizontal placement, and vertical insertion at 15.2, 45.7, and 76.2 cm depths in a clay loam soil with three irrigation treatments. Results indicated the factory-calibrated Acclima 315 L performed satisfactorily using horizontal insertion as compared to NMM measurements at 45.7 and 76.2 cm depths with a ±2% mean difference (MD) and <3.5% root mean square error (RMSE). The fact