Implantable Cardioverter Defibrillators in Patients With Continuous Flow Left Ventricular Assist Devices: Utilization Patterns, Related Procedures, and Complications.
Ontology highlight
ABSTRACT: Background The effect of implantable cardioverter defibrillators ( ICD ) in patients with continuous flow left ventricular assist devices ( LVAD s) on outcomes has not been evaluated in a randomized clinical trial. Methods and Results This is a retrospective single-center study that included patients who underwent continuous flow LVAD implantation at the Cleveland Clinic between October 2004 and March 2017. Patients were evaluated according to the presence or absence of ICD at the time of LVAD insertion. Among 486 patients in the study cohort, 387 (79.6%) had an ICD before LVAD insertion. Patients with ICD before LVAD were older and had lower use of pre- LVAD inotropes, extracorporeal membrane oxygenation, and mechanical ventilation. There were 81 patients (21.4% of patients with ICD ) who
SUBMITTER: Alvarez PA
PROVIDER: S-EPMC6662142 | biostudies-literature | 2019 Jul
REPOSITORIES: biostudies-literature