Cost-Effectiveness of Left Atrial Appendage Closure for Stroke Reduction in Atrial Fibrillation: Analysis of Pooled, 5-Year, Long-Term Data.
Ontology highlight
ABSTRACT: Background Recent publications reached conflicting conclusions about the cost-effectiveness of left atrial appendage closure (LAAC) with the Watchman device (Boston Scientific, Marlborough, MA) for stroke risk reduction in nonvalvular atrial fibrillation (AF). This analysis sought to assess the cost-effectiveness of LAAC relative to both warfarin and nonwarfarin oral anticoagulants (NOACs) using pooled, long-term data from the randomized PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) and PREVAIL (Prospective Randomized Evaluation of the Watchman LAA Closure Device in Patients With Atrial Fibrillation Versus Long-Term Warfarin) trials. Methods and Results A Markov model was constructed from a US payer perspective with a lifetim
SUBMITTER: Reddy VY
PROVIDER: S-EPMC6662368 | biostudies-literature | 2019 Jul
REPOSITORIES: biostudies-literature
ACCESS DATA