Unknown

Dataset Information

Accuracy of computer-assisted vertical cup-to-disk ratio grading for glaucoma screening.


ABSTRACT:

Purpose

Glaucoma screening can be performed by assessing the vertical-cup-to-disk ratio (VCDR) of the optic nerve head from fundus photography, but VCDR grading is inherently subjective. This study investigated whether computer software could improve the accuracy and repeatability of VCDR assessment.

Methods

In this cross-sectional diagnostic accuracy study, 5 ophthalmologists independently assessed the VCDR from a set of 200 optic disk images, with the median grade used as the reference standard for subsequent analyses. Eight non-ophthalmologists graded each image by two different methods: by visual inspection and with assistance from a custom-made publicly available software program. Agreement with the reference standard grade was assessed for each method by calculating th

SUBMITTER: Snyder BM 

PROVIDER: S-EPMC6687168 | biostudies-literature | 2019

REPOSITORIES: biostudies-literature