Deploying Clinical Process Improvement Strategies to Reduce Motion Artifacts and Expiratory Phase Scanning in Chest CT.
Ontology highlight
ABSTRACT: We hypothesized that clinical process improvement strategies can reduce frequency of motion artifacts and expiratory phase scanning in chest CT. We reviewed 826 chest CT to establish the baseline frequency. Per clinical process improvement guidelines, we brainstormed corrective measures and priority-pay-off matrix. The first intervention involved education of CT technologists, following which 795 chest CT were reviewed. For the second intervention, instructional videos on optimal breath-hold were shown to 245 adult patients just before their chest CT. Presence of motion artifacts and expiratory phase scanning was assessed. We also reviewed 311 chest CT scans belonging to a control group of patients who did not see the instructional videos. Pareto and percentage run charts were created for
SUBMITTER: Doda Khera R
PROVIDER: S-EPMC6694170 | biostudies-literature | 2019 Aug
REPOSITORIES: biostudies-literature
ACCESS DATA