Data of dynamic microscale strain distributions of Ti-6Al-4V alloys in dwell fatigue tests.
Ontology highlight
ABSTRACT: Dynamic microscale strain distributions with temporal resolution of 1 s in a smooth and a cracked Ti-6Al-4V alloys during one-cycle dwell fatigue tests are illustrated in videos (URL: https://drive.google.com/drive/folders/1pit_VV2apGOpETVfaJAAtL5Xl2CNOiJ3?usp=sharing). The tensile strain distributions were measured by the video sampling moiré method from the 1-μm-pitch grid images in a scanning electron microscope. The strain concentration factors of the smooth and the cracked specimens are 1.96 and 2.65, respectively. The plastic strain increment is 0.0007 during the displacement holding time of 591s in the smoothed specimen at maximum stress of 900 MPa., and 0.0008 during the displacement holding time of 593s in the cracked specimen at maximum stress of 870 MPa. The typical strain resul
SUBMITTER: Wang Q
PROVIDER: S-EPMC6715821 | biostudies-literature | 2019 Aug
REPOSITORIES: biostudies-literature
ACCESS DATA