Discordance in diagnosis of osteoporosis by quantitative computed tomography and dual-energy X-ray absorptiometry in Chinese elderly men.


ABSTRACT:

Objective

The objective of this study was to investigate the diagnostic discordance of osteoporosis by quantitative computed tomography (QCT) and dual-energy X-ray absorptiometry (DXA) in Chinese elderly men.

Methods

A total of 313 males older than 60 years, who underwent both spinal QCT and lumbar spine and hip DXA in our department, were included. The diagnostic criteria established by the World Health Organisation in 1994 were used for DXA to diagnose osteoporosis, and the criteria recommended by the International Society of Clinical Densitometry were used for QCT. The osteoporosis detection rate by the two techniques was calculated, and the difference was compared. The minor discordance was considered present when the different diagnostic classes between the two techniqu