Ontology highlight
ABSTRACT: Background
One-lung ventilation (OLV) in thoracic anesthesia is required to provide good surgical exposure. OLV is commonly achieved through a double lumen tube (DLT) or a bronchial blocker (BB). Malposition is a relevant issue related to these devices use. No prospective studies with adequately large sample size have been performed to evaluate the malposition rate of DLTs and BBs.Methods
A total of 2,127 patients requiring OLV during thoracic surgery were enrolled. The aim of this multicenter prospective observational study performed across 26 academic and community hospitals is to evaluate intraoperative malposition rate of DLTs and BBs. We also aim to assess: which device is the most used to achieve OLV, the frequency of bronchoscope (BRO) use, the incidence rate of desa
SUBMITTER: Langiano N
PROVIDER: S-EPMC6753428 | biostudies-literature | 2019 Aug