Creep Damage Assessment of Ex-Service 12% Cr Power Plant Steel Using Digital Image Correlation and Quantitative Microstructural Evaluation.
Ontology highlight
ABSTRACT: The lifetime of steam pipelines in long-term operation in coal-fired power plants are limited due to material damage that resulted from creep exposure. In the present study, the authors comparatively assess the damage of ex-service 12% Cr piping steel with varying degrees of exposure while using accelerated creep tests that employ digital image correlation (DIC) as well as microstructural investigation that is based on electron microscopy. The DIC technique, which allows multiple creep curves to be measured at temperatures ranging from 550-600 °C from a single specimen, revealed higher Zener-Hollomon parameters for a high damage material with a high void density when compared to a material with lower damage and lower void density. Both of the material states showed similar hardness values,
SUBMITTER: van Rooyen M
PROVIDER: S-EPMC6804267 | biostudies-literature | 2019 Sep
REPOSITORIES: biostudies-literature
ACCESS DATA