Project description:Background and aimsAccessing the pancreatobiliary region in patients with a history of Roux-en-Y gastric bypass (RYGB) can be challenging. Traditionally, techniques such as percutaneous biliary drainage, enteroscopy-assisted ERCP, and laparoscopy-assisted ERCP have been used. However, each technique has its limitations. EUS-directed transgastric ERCP (EDGE) using a lumen-apposing metal stent (LAMS) has emerged as a novel endoscopic technique for ERCP in patients who have undergone RYGB. The aim of this case series was to highlight LAMS-related shortcomings and adverse events during the periprocedural period.MethodsThis was a retrospective review of 4 patients with RYGB anatomy who underwent EDGE for the management of pancreaticobiliary disease and experienced LAMS-related adverse events. Techniques for managing and avoiding these events are discussed.ResultsFour patients underwent EDGE with both technical and clinical success. Slight LAMS migration with partial mucosal overgrowth was encountered in 1 case and was managed by LAMS removal. A large, bleeding, distal marginal ulcer after the EDGE procedure was encountered in the second case and was managed with proton pump inhibitor and removal of the LAMS, with fistula treatment with argon plasma coagulation used to enhance closure. The third case was complicated by moderate intraprocedural bleeding after LAMS dilation, which was managed by applying balloon tamponade and placing a through-the-scope esophageal stent across the LAMS. Last, preferential food passage to the excluded stomach was noted in the fourth case and resulted in symptomatic distention. The symptomatic distention was managed by another de novo jejunogastrostomy using a LAMS for drainage.ConclusionsDespite its feasibility and acceptable safety profile, the use of LAMSs during EDGE could be associated with several procedure-specific adverse events, which can be avoided or managed endoscopically with no further consequence.
Project description:BACKGROUND : Endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (EDGE) has emerged as a viable completely endoscopic method for performing pancreaticobiliary interventions in patients with Roux-en-Y gastric bypass anatomy. The aims of this systematic review were: (1) to describe the indications, outcomes, and complications of EDGE; and (2) to identify deficiencies in our knowledge of important technical approaches and clinical outcomes. METHODS : A systematic review was conducted via comprehensive searches of Medline, Scopus, CINAHL, and Cochrane to identify studies focusing on EDGE outcomes. Simple descriptive statistics were derived from case series only. Case reports were only included to qualitatively describe additional indications, techniques, and adverse events. RESULTS : The initial search identified 2143 abstracts. Nine case series and eight case reports were included. In the nine case series, 169 patients underwent EDGE. The technical success rate was 99 % (168 /169) for gastrogastrostomy/jejunogastrostomy creation and 98 % (166 /169) for subsequent ERCP. Minor adverse events specifically related to EDGE occurred in 18 % (31/169) and included intraprocedural stent migration/malposition (n = 27) and abdominal pain (n = 4). Moderate adverse events specific to EDGE occurred in 5 % (9/169): including bleeding (2 %), persistent fistula (1 %), and perforation (1 %). Severe adverse events occurred in one patient with a perforation requiring surgery. Deficiency in reporting on the clinical significance of adverse events was identified. CONCLUSION : Based on limited observational data, in expert hands, EDGE has a high rate of technical success and an acceptable rate of adverse events. As a novel procedure, many knowledge gaps need to be addressed to inform the design of meaningful comparative studies and guide informed consent.