Unknown

Dataset Information

Thin Degradable Coatings for Optimization of Osteointegration Associated with Simultaneous Infection Prophylaxis.


ABSTRACT: One of the most common causes of implant failure is aseptic prosthesis loosening. Another frequent complication after prosthesis implant is the microbial colonization of the prosthesis surface, which often leads to a replacement of the prosthesis. One approach to reduce these complications is the application of bioactive substances to implant surfaces. Both an antibiotic prophylaxis and a faster osteointegration can be obtained by incorporation of bactericidal active metals in degradable calcium phosphate (CaP) coatings. In this study, thin degradable calcium phosphate ceramic coatings doped with silver (Ag), copper (Cu), and bismuth (Bi) on a titanium substrate were prepared with the aid of the high-velocity suspension flame spraying (HVSFS) coating process. To characterize the samples su

SUBMITTER: Burtscher S 

PROVIDER: S-EPMC6862457 | biostudies-literature | 2019 Oct