Removal efficiency of central vacuum system and protective masks to suspended particles from dental treatment.


ABSTRACT:

Background

High levels of suspended particulate matters (PMs) and bioaerosols are created by dental procedures. The present study aimed to evaluate the size and concentration of PMs produced by drilling and grinding teeth, and to assess the efficiency of central vacuum system and protective masks for the removal of PMs.

Methods

A total of 20 extracted permanent teeth were collected. A novel experimental system and particle counter were used to evaluate the PMs produced by dental procedures and the PM removal efficiency of a central vacuum system and surgical/N95 masks.

Results

The number concentration of total PMs produced by drilling and grinding teeth was significantly higher than the indoor background concentration. The average aerodynamic diameter of particle was

SUBMITTER: Liu MH 

PROVIDER: S-EPMC6879156 | biostudies-literature | 2019