Chlorine Dioxide Degradation Issues on Metal and Plastic Water Pipes Tested in Parallel in a Semi-Closed System.
Ontology highlight
ABSTRACT: Chlorine dioxide (ClO2) has been widely used as a disinfectant in drinking water in the past but its effects on water pipes have not been investigated deeply, mainly due to the difficult experimental set-up required to simulate real-life water pipe conditions. In the present paper, four different kinds of water pipes, two based on plastics, namely random polypropylene (PPR) and polyethylene of raised temperature (PERT/aluminum multilayer), and two made of metals, i.e., copper and galvanized steel, were put in a semi-closed system where ClO2 was dosed continuously. The semi-closed system allowed for the simulation of real ClO2 concentrations in common water distribution systems and to simulate the presence of pipes made with different materials from the source of water to the tap. Results s
SUBMITTER: Vertova A
PROVIDER: S-EPMC6888174 | biostudies-literature | 2019 Nov
REPOSITORIES: biostudies-literature