Ontology highlight
ABSTRACT: Purpose
To demonstrate the feasibility of detecting patency, stenosis, or occlusion of transjugular intrahepatic portosystemic shunt (TIPS) with four-dimensional (4D) flow MR imaging.Materials and methods
Sequential adult patients with TIPS were eligible for enrollment. Volumetric phase-contrast sequence was used to image TIPS. Particle tracing cine images were used for qualitative assessment of stenosis. TIPS was segmented to generate quantitative data sets of peak velocity. Segmentation and quantitative measurement of flow throughout an entire TIPS defined technical success. Doppler US was used for comparison. Venography, when available, and 6-month clinical follow-up were used as reference standards.Results
4D flow MR imaging was performed in 23 patient encounter
SUBMITTER: Owen JW
PROVIDER: S-EPMC6951427 | biostudies-literature | 2018 Dec
REPOSITORIES: biostudies-literature