Unknown

Dataset Information

Sources of error and variability in particulate matter sensor network measurements.


ABSTRACT: The quality of mass concentration estimates from increasingly popular networks of low-cost particulate matter sensors depends on accurate conversion of sensor output (e.g., voltage) into gravimetric-equivalent mass concentration, typically using a calibration procedure. This study evaluates two important sources of variability that lead to error in estimating gravimetric-equivalent mass concentration: the temporal changes in sensor calibration and the spatial and temporal variability in gravimetric correction factors. A 40-node sensor network was deployed in a heavy vehicle manufacturing facility for 8 months. At a central location in the facility, particulate matter was continuously measured with three sensors of the network and a traditional, higher-cost photometer, determining the calib

SUBMITTER: Zuidema C 

PROVIDER: S-EPMC6954050 | biostudies-literature | 2019 Aug

REPOSITORIES: biostudies-literature