Unknown

Dataset Information

0

Multicenter Evaluation of the New Etest Gradient Diffusion Method for Piperacillin-Tazobactam Susceptibility Testing of Enterobacterales, Pseudomonas aeruginosa, and Acinetobacter baumannii Complex.


ABSTRACT: Piperacillin-tazobactam (P/T) is a β-lactam-β-lactamase inhibitor combination frequently used in the hospital setting. Etest is a gradient diffusion method that represents an alternative to broth microdilution (BMD) for performing antimicrobial susceptibility testing. We conducted a multicenter evaluation of the performance of the new P/T Etest compared to that of BMD following U.S. Food and Drug Administration (FDA) and International Standards Organization (ISO) standard ISO 20776-2 criteria using Clinical and Laboratory Standards Institute (CLSI)-FDA and European Committee on Antimicrobial Susceptibility Testing (EUCAST) interpretive breakpoints, respectively. A total of 977 isolates (775 Enterobacterales isolates, 119 Pseudomonas aeruginosa isolates, and 83 Acinetobacter baumannii complex isolates) were tested. Overall essential agreement (EA) was 96.4% and 96.6% for Enterobacterales when FDA and ISO 20776-2 criteria, respectively, were followed. EA was 98.3% for P. aeruginosa and 91.6% for the A. baumannii complex when both the FDA and ISO criteria were followed. Applying CLSI-FDA breakpoints, categorical agreement (CA) reached 93.0%, 93.3%, and 89.2% for the Enterobacterales, P. aeruginosa, and the A. baumannii complex, respectively. Two very major errors (VMEs; 1.1%) were found among the Enterobacterales (for 2 Klebsiella pneumoniae isolates). No additional major errors (MEs) or VMEs were found. Applying EUCAST breakpoints, CA was 94.8% and 95.8% for Enterobacterales and P. aeruginosa, respectively (no breakpoints are currently available for the A. baumannii complex). No VMEs were observed among the Enterobacterales, but 2 (0.4%) MEs were found. Among the P. aeruginosa isolates, 2 (6.9%) VMEs and 3 (3.3%) MEs were observed. These errors resulted when P/T Etest MICs were 1 doubling dilution apart from the BMD MICs. In conclusion, the new P/T Etest represents an accurate tool for performing antimicrobial susceptibility testing of Enterobacterales, P. aeruginosa, and A. baumannii complex isolates with limited category errors.

SUBMITTER: Garcia-Fernandez S 

PROVIDER: S-EPMC6989064 | biostudies-literature | 2020 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Multicenter Evaluation of the New Etest Gradient Diffusion Method for Piperacillin-Tazobactam Susceptibility Testing of <i>Enterobacterales</i>, <i>Pseudomonas aeruginosa</i>, and <i>Acinetobacter baumannii</i> Complex.

García-Fernández Sergio S   Bala Yohann Y   Armstrong Tom T   García-Castillo María M   Burnham C A CA   Wallace Meghan A MA   Hardy Dwight D   Zambardi Gilles G   Cantón Rafael R  

Journal of clinical microbiology 20200128 2


Piperacillin-tazobactam (P/T) is a β-lactam-β-lactamase inhibitor combination frequently used in the hospital setting. Etest is a gradient diffusion method that represents an alternative to broth microdilution (BMD) for performing antimicrobial susceptibility testing. We conducted a multicenter evaluation of the performance of the new P/T Etest compared to that of BMD following U.S. Food and Drug Administration (FDA) and International Standards Organization (ISO) standard ISO 20776-2 criteria us  ...[more]

Similar Datasets

| S-EPMC6113460 | biostudies-literature
| S-EPMC5890698 | biostudies-literature
| S-EPMC7325266 | biostudies-literature
| S-EPMC9312067 | biostudies-literature
| S-EPMC7526819 | biostudies-literature
| S-EPMC10668787 | biostudies-literature
| S-EPMC9237110 | biostudies-literature
| S-EPMC7368386 | biostudies-literature
| S-EPMC7037351 | biostudies-literature