Testing the Use of Static Chamber Boxes to Monitor Greenhouse Gas Emissions from Wood Chip Storage Heaps.


ABSTRACT: This study explores the use of static chamber boxes to detect whether there are fugitive emissions of greenhouse gases (GHGs) from a willow chip storage heap. The results from the boxes were compared with those from 3-m stainless steel probes inserted into the core of the heap horizontally and vertically at intervals. The results from probes showed that there were increases of carbon dioxide (CO2) concentrations in the heap over the first 10 days after heap establishment, which were correlated with a temperature rise to 60 °C. As the CO2 declined, there was a small peak in methane (CH4) concentration in probes orientated vertically in the heap. Static chambers positioned at the apex of the heap detected some CO2 fluxes as seen in the probes; however, the quantities were small and random in