Vent pipe emissions from storage tanks at gas stations: Implications for setback distances.
Ontology highlight
ABSTRACT: At gas stations, fuel vapors are released into the atmosphere from storage tanks through vent pipes. Little is known about when releases occur, their magnitude, and their potential health consequences. Our goals were to quantify vent pipe releases and examine exceedance of short-term exposure limits to benzene around gas stations. At two US gas stations, we measured volumetric vent pipe flow rates and pressure in the storage tank headspace at high temporal resolution for approximately three weeks. Based on the measured vent emission and meteorological data, we performed air dispersion modeling to obtain hourly atmospheric benzene levels. For the two gas stations, average vent emission factors were 0.17 and 0.21 kg of gasoline per 1000 L dispensed. Modeling suggests that at one gas station,
SUBMITTER: Hilpert M
PROVIDER: S-EPMC7059886 | biostudies-literature | 2019 Feb
REPOSITORIES: biostudies-literature
ACCESS DATA