Unknown

Dataset Information

The cotton test redistributes nasal airflow in patients with empty nose syndrome.


ABSTRACT:

Background

Empty nose syndrome (ENS) remains a controversial disease primarily associated with inferior turbinate tissue loss. Cotton placement into the inferior meatus often alleviates ENS symptoms within minutes, but the physiologic explanation for this phenomenon is unknown. Computational fluid dynamics (CFD) was employed to evaluate the mechanisms of altered nasal airflow conferred by cotton testing.

Methods

Six ENS patients (12 sides) with pre-existing sinus computed tomography (CT) imaging were enrolled after marked symptomatic improvement (decrease in score on the Empty Nose Syndrome 6-Item Questionnaire [ENS6Q] of >7 points) with office-based cotton testing. The fashioned cotton plug was labeled in situ with iohexol contrast spray, and sinus CT was immediately obtain

SUBMITTER: Malik J 

PROVIDER: S-EPMC7182493 | biostudies-literature | 2020 Apr

REPOSITORIES: biostudies-literature