Unknown

Dataset Information

Removal of Boron and Manganese Ions from Wet-Flue Gas Desulfurization Wastewater by Hybrid Chitosan-Zirconium Sorbent.


ABSTRACT: Flue gas desulfurization (FGD) wastewater, after the alkaline precipitation and coagulation processes, often requires additional treatment in order to reduce the concentrations of boron and heavy metals below the required limits. In this study, we present an innovative and environmentally friendly method for boron and manganese removal that is based on a hybrid chitosan-zirconium hydrogel sorbent. The results from the batch adsorption experiment indicated that the uptake capacity for boron and manganese was equal to 1.61 mg/g and 0.75 mg/g, respectively, while the column study indicated that the total capacity of boron and manganese was equal to 1.89 mg/g and 0.102 mg/g, respectively. The very good applicability of the Langmuir isotherm at 25 °C suggested the monolayer coverage of the boro

SUBMITTER: Kluczka J 

PROVIDER: S-EPMC7183067 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature