Ontology highlight
ABSTRACT: Purpose
To evaluate the long-term in vivo degradation of an amorphous stereoisomer combined with micro β-tricalcium phosphate poly levo (96%)/dextro (4%) lactide beta-tricalcium phosphate biocomposite interference screw.Methods
A study approved by the institutional review board of in vivo biologic behavior of the screw was initiated in 2011 using an anterior cruciate ligament (ACL) reconstruction model. Twenty patients undergoing bone-patellar tendon-bone ACL reconstruction fixed at the femur and tibia with these biocomposite screws followed at least 36 months were evaluated by physical, radiographic, and computed tomography (CT) evaluations. Lysholm, Tegner, Cincinnati, and International Knee Documentation Committee scores were obtained. CT Hounsfield unit (HU) data were o
SUBMITTER: Barber FA
PROVIDER: S-EPMC7190552 | biostudies-literature | 2020 Apr
REPOSITORIES: biostudies-literature