Unknown

Dataset Information

Intraoperative Patella Dimension Measurement in Asian Female Patients and Its Relevance in Patellar Resurfacing in TKA.


ABSTRACT:

Background

Implants used for total knee arthroplasty (TKA) in Asian patients are mostly produced based on anthropometry of the Western population, thus causing problem with patella sizing, especially in Asian females where the patellae are regarded to be smaller. This study is to define intraoperative patella dimensions in our female populations and compare them with current prosthetic systems available at our institution.

Methods

This is a cross-sectional study involving 156 TKA female patients with normal patellae. The patella height, width, thickness, medial and lateral articular facets' width and thickness, and the dome position were measured. The smallest implant size from 3 manufacturers was compared to the data obtained. Analysis using descriptive statistics was used

SUBMITTER: Ab Rahman S 

PROVIDER: S-EPMC7210516 | biostudies-literature | 2020