Unknown

Dataset Information

Low-Frequency Hearing Preservation With Long Electrode Arrays: Inclusion of Unaided Hearing Threshold Assessment in the Postoperative Test Battery.


ABSTRACT: Purpose The goal of this work was to evaluate the low-frequency hearing preservation of long electrode array cochlear implant (CI) recipients. Method Twenty-five participants presented with an unaided hearing threshold of ≤ 80 dB HL at 125 Hz pre-operatively in the ear to be implanted. Participants were implanted with a long (31.5-mm) electrode array. The unaided hearing threshold at 125 Hz was compared between the preoperative and postoperative intervals (i.e., initial CI activation, and 1, 3, 6, 9, and 12 months after activation). Results Eight participants maintained an unaided hearing threshold of ≤ 80 dB HL at 125 Hz postoperatively. The majority (n = 5) demonstrated aidable low-frequency hearing at initial activation, whereas 3 other participants experienced an improvement in

SUBMITTER: Dillon MT 

PROVIDER: S-EPMC7229778 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature