Severe low cerebral oximetry in difficult cardiopulmonary bypass weaning of low body-weight infant: a case report and literature review.


ABSTRACT:

Background

For infants undergoing complex cardiac surgery, hemodynamic management after cardiopulmonary bypass (CPB) is challenging because of severe myocardial edema, vasomotor dysfunction and weak tolerance to a change in blood volume. More importantly, the lack of availability of equipment for advanced monitoring, such as transesophageal echocardiography or transthoracic echocardiography, restricts the accurate assessment of hemodynamics.

Case presentation

This is a case of severe hypotension and non-detectable pulse oxygen saturation (SpO2) after CPB in a low-weight infant who had normal blood pressure and oxygen saturation before surgery. Epinephrine and milrinone were administered with cerebral oximetry monitoring rather than blood pressure measurements beca

SUBMITTER: Hao X 

PROVIDER: S-EPMC7320539 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature