Ontology highlight
ABSTRACT: Background
Extracorporeal membrane oxygenation (ECMO) use in patients with active bleedings or traumatic injuries may be challenging because of the risk of refractory haemorrhage related to systemic anticoagulation (SA). Technological advancements, especially heparin coated circuits, allowed ECMO application with a mild or no anticoagulation regimen in some circumstances. We herein report a limited case-series of ECMO application without anticoagulation.Methods
ECMO without SA was established in 6 patients. Four of them received veno-arterial mode. Full heparin antagonization with protamine was provided in 3 post-cardiotomy cases. Tip-to-tip heparin-coated ECMO circuit was used in 4 patients, whereas heparin-coated tubing and no heparin-coated cannulas were applied for the
SUBMITTER: Fina D
PROVIDER: S-EPMC7330289 | biostudies-literature | 2020 May